Thermostat Wire (LVT)

AWG / Cond Conductor Shielding Standard Packaging (ft) Riser Plenum
18/2 Solid Bare Copper Unshielded 500' Spool 7032 7033
18/3 Solid Bare Copper Unshielded 500' Spool 7137 7138
18/4 Solid Bare Copper Unshielded 250' Spool 7232 7233
18/5 Solid Bare Copper Unshielded 250' Spool 7337 7338
18/6 Solid Bare Copper Unshielded 250' Spool 7432 7433
18/7 Solid Bare Copper Unshielded 250' Spool 7442 7443
18/8 Solid Bare Copper Unshielded 250' Spool 7537 7538
18/10 Solid Bare Copper Unshielded 250' Spool 7547 7548
18/12 Solid Bare Copper Unshielded 250' Spool 7557 7558
20/2 Solid Bare Copper Unshielded 500' Spool 7632 7633
20/3 Solid Bare Copper Unshielded 500' Spool 7642 7643
20/4 Solid Bare Copper Unshielded 500' Spool 7634 7635
20/5 Solid Bare Copper Unshielded 500' Spool 7636 7637
20/6 Solid Bare Copper Unshielded 250' Spool 7646 7647
20/7 Solid Bare Copper Unshielded 250' Spool 7656 7657
20/8 Solid Bare Copper Unshielded 250' Spool 7638 7639

Questions installers ask before choosing thermostat wire

Use these checks to match the cable to the equipment, pathway, and installation environment before selecting a part number.

What is thermostat wire used for?

Thermostat wire carries low-voltage control signals between thermostats, HVAC equipment, zone controls, and compatible control devices.

Should I choose 18 AWG or 20 AWG thermostat wire?

18 AWG has lower electrical resistance and greater mechanical strength than 20 AWG. Follow the equipment specification, pathway conditions, run length, and locally adopted code.

How many conductors do I need?

Count every required equipment terminal, including the C-wire, heating and cooling stages, fan, heat-pump functions, and accessories. Include practical spare conductors when appropriate.

Does a smart thermostat require a C-wire?

Many smart thermostats need a common or C-wire for continuous 24-volt power, but requirements differ by model. Verify the thermostat and HVAC equipment instructions.

Should I choose plenum-rated or riser-rated cable?

Use CMP/CL3P cable where a plenum rating is required. CMR/CL3R cable is intended for permitted riser and general pathways.

Can riser-rated thermostat wire be installed in a plenum space?

Do not substitute a riser rating where a plenum rating is required. Confirm the pathway classification and locally adopted electrical and building codes.

What do FT4 and FT6 mean?

FT4 and FT6 are Canadian flame-test designations commonly associated with riser and plenum applications. Verify the required marking for the project’s jurisdiction.

Does sunlight resistance mean the cable can be buried outdoors?

No. Sunlight resistance does not automatically provide direct-burial, wet-location, or underground approval. Check the complete cable listing and installation environment.

Do thermostat wire colors always identify their function?

No. Colors are conventions, not guarantees. Identify conductors by their equipment terminals and wiring diagrams, then label them before disconnecting anything.

Can thermostat wire also be used for a doorbell?

It may be suitable for compatible low-voltage control circuits when its conductor size, listing, voltage, and environmental rating meet the equipment and code requirements.

Can I reuse existing thermostat cable?

Reuse it only after checking its insulation condition, conductor count, pathway rating, continuity, terminal mapping, and compatibility with the new equipment.

Can thermostat wire share a pathway with line-voltage wiring?

Low-voltage control wiring may require separation, barriers, or approved wiring methods. Follow NEC Article 725 and the requirements adopted by the local authority.

Should thermostat-wire splices remain accessible?

Avoid concealed, undocumented splices. When a splice is necessary, use an approved accessible location and suitable connectors according to the applicable code and equipment instructions.

What should I avoid while pulling the cable?

Avoid excessive pulling force, sharp bends, crushed insulation, staples driven too tightly, and contact with damaging edges or unsuitable environments.

What should be tested after installation?

Verify conductor continuity, absence of shorts, terminal assignments, equipment operation, and any required control functions. Label and document the completed installation.

What should I verify before ordering a part number?

Confirm the gauge, conductor count, pathway rating, environmental exposure, required footage, equipment terminals, jurisdictional markings, and practical spare capacity.

Continue your research: Read the digital thermostat wiring guide · Review thermostat wire color conventions · Browse thermostat wire products

Brochure

Syston Thermostat Wire (LVT) Brochures

FAQs

Thermostat Wire (LVT) frequently asked questions

Blog

Explore Syston Thermostat Wire (LVT)’s blog updates

Become A Distributor

Syston Cable Technology believes in identifying, building and nurturing long term distributor partnerships. We seek well run, established and properly resourced distributor partners that want to grow their business as much as we want to grow ours. Our partnerships begins with our portfolio of high performance cable products with the most competitive price and our well known brands, and continue with an array of support materials and programs to insure our distributor partners are successful in their respective marketplaces.

If you or your company is up for the challenge, and the rewards that come with being a distributor partner, please take a few minutes to complete the application form below and click the SUBMIT button at the bottom. Upon review, we will contact you to complete the application process. All applications are reviewed within 48 hours. 

SYSTON Sales

SYSTON Resources

Spread the love
Translate »