EZ-Pull Premium 18/2 Thermostat Wire (LVT)

18 AWG, 2 Conductors, Solid Copper
Riser Rated – CMR, CL3R, FT4, Sunlight Resistant

Verified thermostat cable details

Specify the exact SKU. Install with confidence.

Use the product title, visible specifications, and documents on this page to confirm gauge, conductor count, conductor material, and CMR/CMP pathway rating before ordering.

Sun resistant familyExact-SKU documentation
Applications

Where this thermostat cable fits

Thermostat control runs

Connect wall thermostats to furnaces, air handlers, and other low-voltage HVAC controls using the verified conductor count shown above.

Heat-pump and multi-stage controls

Higher conductor-count variants support additional control functions when the equipment diagram calls for them.

Smart-thermostat preparation

Check the available common (C) conductor and the thermostat manufacturer requirements before replacing a control.

Shopper questions

Answers for this exact product page

What gauge is this cable?

Use the gauge shown in the product title and Specifications section for this SKU.

How many conductors are included?

Use the conductor count shown in the product title and Specifications section for this SKU.

Is this construction CMR or CMP?

The product title and rating attributes identify the pathway rating. CMR is riser-rated; CMP is plenum-rated.

What jacket description applies?

CMR products use “Premium PVC (Flame-Retardant, Sun Resistant & RoHS Compliant).” CMP products use “Plenum PVC (Flame-Retardant, Sun Resistant & RoHS Compliant).”

Is this thermostat cable sunlight resistant?

All thermostat cables in this family are treated as sunlight resistant. Confirm the complete installation pathway and project requirements.

Is the conductor solid copper?

Confirm conductor material in the verified Specifications section for this SKU.

Can I use it for a smart thermostat?

Confirm the smart thermostat's wiring and power requirements, including whether a common (C) conductor is needed.

Can I use it in a plenum?

Only products identified as CMP/plenum-rated should be selected where the project requires plenum cable.

Can I use it in a riser pathway?

Products identified as CMR/riser-rated are the relevant choice when the project requires a riser rating.

Where is the datasheet?

Use the documents/downloads area on this page and verify that the document matches this SKU.

What terminals may be present on my thermostat?

Common labels include R, Rc, Rh, C, W, Y, G, and O/B. Follow the equipment and thermostat instructions.

Does conductor color determine terminal function?

Color conventions help identification, but terminal labels and the equipment wiring diagram control the installation.

What package length is available?

Check the exact SKU's options and documents. The confirmed 18/4 family package length is 500 ft for SKUs 7232 and 7233.

Can I substitute a different conductor count?

Do not substitute without confirming the equipment diagram, control sequence, and project specification.

What should I verify before purchase?

Confirm gauge, conductor count, material, CMR/CMP rating, package length, and the pathway requirements.

Who can help with selection?

Contact Syston technical support with the SKU, equipment model, conductor count, and pathway details.

Related guides

Plan the install before you pull cable

Read the digital thermostat wiring guide for terminal planning and the thermostat color-code guide for conductor identification. Return to the thermostat-wire category to compare adjacent SKUs.

Request a quoteTalk to technical support

Engineering note → Verify the exact product specifications and documents against the equipment manufacturer's instructions and project requirements before installation.

EZ-Pull® Premium 18/2 Thermostat Wire from Syston: 18 AWG, 2-conductor solid copper cable with CMR / CL3R / FT4 ratings for specified HVAC control runs.

Description

EZ-Pull® · Thermostat wire

18/2 CMR
Thermostat Wire

SYSTON PART 7032

18 AWG, two-conductor solid bare-copper cable for specified low-voltage HVAC controls. CMR / CL3R / FT4 ratings, with Brown or White jackets and a standard 500 ft package.

  • 18 AWG · 2 conductors
  • Solid bare copper
  • CMR / CL3R / FT4
Syston Part 7032 18/2 solid-copper thermostat cable product image
Part 7032 · 18 AWG, 2 conductors
Brown and White jacket options. Confirm the required configuration when ordering.

Construction, clearly stated

The details that
help you specify.

Start with conductor count, construction and cable rating. Confirm the equipment requirements and pathway before placing your order.

01 / CONDUCTORS

Solid bare copper.

Two 18 AWG conductors with Red and White identification for specified two-conductor control circuits.

02 / CABLE RATINGS

CMR / CL3R / FT4.

Published ratings for Part 7032. Review the project pathway requirements; this product is not the CMP plenum option.

03 / HANDLING

Details for the pull.

A longitudinal ripcord beneath the PVC jacket and standard 500 ft packaging support cable preparation and ordering.

Product specifications

Know what
you are ordering.

Key construction, rating and packaging information for Syston Part 7032.

View the technical data sheet ↗

Sunlight resistance does not establish wet-location or direct-burial suitability. Confirm the complete application and required markings.
Part 7032 · Published product parameters
Part number 7032
Conductor size / count 18 AWG / 2 conductors
Conductor Solid bare copper
Conductor identification Red / White
Cable ratings CMR / CL3R / FT4
Insulation Polyolefin
Jacket PVC; sunlight resistant
Maximum operating voltage 300 V (published technical sheet)
Nominal cable diameter 0.130 in
Installation temperature +32°F to +140°F
Storage & operation −4°F to +167°F
Standard package 500 ft
Jacket colors Brown / White
Ripcord Longitudinally under the jacket

Nominal dimensions are not guaranteed maximum dimensions. Confirm current documentation and project requirements before final specification.

Ordering options

Two jacket colors.
One base part number.

BrownWhite

Standard package: 500 ft. Custom lengths, colors, construction and packaging may be requested. Syston will confirm available combinations, complete ordering SKU, pricing and lead time.

Provide the jacket color, quantity, package requirements and delivery location with your inquiry.

Typical applications

Specified low-voltage control circuits.

  • Thermostat and HVAC control wiring.
  • Heating and air-conditioning equipment controls.
  • Doorbell and other compatible low-voltage circuits.

Part 7032 provides two conductors. Equipment requiring additional terminals or a common connection may require a different conductor count.

Syston supplies wire and cable products. Consult a qualified electrician or engineer for system design, code applicability and installation questions.

Product questions

Answers before
you order.

Start with the common questions below. More detailed product and pathway questions remain available in the expanded reference section.

What does 18/2 thermostat wire mean?
The “18/2” description means the cable contains two 18 AWG insulated conductors. Part 7032 uses solid bare-copper conductors with red and white insulation inside a round thermostat-cable jacket. It is intended for specified low-voltage HVAC control runs; always confirm the conductor count and pathway before selection.Sources: Syston data sheet
Is Part 7032 solid copper or CCA?
Part 7032 is specified with two 18 AWG solid bare-copper conductors. It is not identified in the approved Part 7032 record as copper-clad aluminum (CCA). “Solid” describes each conductor as a single copper core rather than a stranded bundle. Follow the connected equipment’s stripping and termination instructions before making the final connection.Sources: Syston data sheet
Can Part 7032 support a smart thermostat?
Part 7032 may be considered only when the thermostat and HVAC equipment wiring diagrams call for a two-conductor control run. Many smart thermostats require additional conductors or a dedicated common connection. Do not infer compatibility from the thermostat-wire name alone; confirm every terminal and power requirement with the equipment manufacturer.Sources: Syston data sheet · Syston thermostat wiring guide
When is CMP required instead of CMR?
CMP is the plenum-rated option used where the pathway is classified as a plenum or another space that requires plenum cable. CMR is a riser rating and must not be treated as a substitute where CMP is required. Confirm the actual space classification with project documents, local code, and the authority having jurisdiction.Sources: Syston riser-versus-plenum guide · UL application guide · UL cable testing context · NFPA 70
How do I confirm that two conductors are enough?
List the required control terminals at both ends of the run and compare them with the equipment wiring diagram. Part 7032 provides exactly two insulated conductors. If the system requires separate heating, cooling, fan, common, reversing-valve, accessory, or other functions, select a verified conductor count that supports the complete design.Sources: Syston data sheet · Syston thermostat wiring guide
Can this product be used outdoors, in wet locations, or for direct burial?
The Part 7032 Premium PVC jacket is identified by the manufacturer as sunlight resistant for specified above-ground pathways. That statement does not independently establish wet-location, underground, direct-burial, or unrestricted outdoor approval. Confirm the complete route, enclosure, moisture exposure, temperature, pathway classification, project documents, local code, and AHJ requirements before installation.Sources: Syston data sheet
More product questions · 14 answers
How should buyers interpret 18 AWG?
18 AWG is the American Wire Gauge size of each conductor in Part 7032. It identifies conductor size, but it does not establish system compatibility by itself. The equipment wiring diagram, circuit requirements, run design, pathway rating, and local rules must all be reviewed before the cable is specified or installed.Sources: Syston data sheet · Syston AWG guide
What does two-conductor construction provide?
Two-conductor construction provides one red and one white insulated conductor inside the outer jacket. This can suit control circuits that require two conductors, but it does not support every thermostat or HVAC configuration. Count every required terminal and function on the equipment wiring diagram before ordering Part 7032.Sources: Syston data sheet
Do Brown and White jackets differ technically?
Brown and White are visual jacket options for the same Part 7032 construction. The published product specifications do not assign different electrical, flame-test, pathway, or environmental performance to the two colors. Choose the color that supports project identification, then confirm current package availability and ordering details with Syston.Sources: Syston data sheet
What does the CMR rating mean?
CMR identifies a communications riser cable rating. It is associated with vertical riser pathways and the applicable flame-test requirements for that cable type. Part 7032 is marked CMR, but the rating does not independently approve every route. Confirm the planned pathway with project documents, local code, and the authority having jurisdiction.Sources: Syston data sheet · Syston NEC and flame-test guide · UL application guide · UL cable testing context · NFPA 70
What does the CL3R designation mean?
CL3R identifies a Class 3 riser cable designation under the applicable National Electrical Code framework. It describes the listed cable type and intended pathway category; it is not a substitute for a project-specific installation review. Confirm circuit classification, route, equipment instructions, and local requirements before using Part 7032.Sources: Syston data sheet · Syston NEC and flame-test guide · UL application guide · NFPA 70
What does FT4 indicate?
FT4 is a CSA vertical cable-tray flame-test classification. It indicates performance under the referenced vertical tray flame-test method; it does not, by itself, establish universal Canadian approval or suitability for every installation. Confirm all required product markings, certifications, provincial or local rules, and project specifications before installation.Sources: Syston data sheet · Syston CSA flame-test guide · CSA Wire and Cable No. 198
Can Part 7032 be used for furnace controls?
Part 7032 is intended for specified low-voltage HVAC control wiring and may fit a furnace control connection that requires two conductors. Suitability depends on the furnace wiring diagram, terminal functions, circuit classification, route, and local requirements. Confirm all five before the cable is ordered or installed.Sources: Syston data sheet · NFPA 70
Can Part 7032 be used for air-handler controls?
It may be used for an air-handler control run when the equipment documentation specifies a compatible two-conductor low-voltage circuit. Do not assume that every air handler uses the same terminal arrangement. Verify the control-board diagram, required conductor count, pathway classification, and applicable local rules before installation.Sources: Syston data sheet · NFPA 70
What should be confirmed before routing the cable?
Confirm the pathway classification, environmental exposure, required rating, support method, bend and pulling conditions, separation from other systems, equipment instructions, and local code. The CMR / CL3R / FT4 and sunlight-resistant markings describe verified product attributes, but they do not replace an installation-specific review or approval.Sources: Syston data sheet · Syston NEC and flame-test guide · UL application guide · NFPA 70
What information should I verify before ordering?
Confirm Part Number 7032, 18 AWG, two conductors, solid copper, CMR / CL3R / FT4 ratings, Brown or White jacket, the standard 500-foot package or requested custom length, and the required project quantity. Also verify that the pathway and equipment diagram match a two-conductor riser-rated thermostat cable before placing the order.Sources: Syston data sheet
How are the two conductors identified?
Part 7032 uses one red insulated conductor and one white insulated conductor inside the outer jacket. Keep the identification consistent from the source equipment to the field device, and label the run when the project requires it. Conductor color does not replace verification against the equipment wiring diagram.Sources: Syston data sheet · Syston thermostat color guide · Syston cable-marking guide
Who confirms code compliance for the installation?
The installer and project team should verify the design against the adopted local code, project specifications, equipment instructions, and the authority having jurisdiction, often abbreviated AHJ. Product markings help identify the cable type, but they do not approve a specific pathway or installation on their own.Sources: Syston NEC and flame-test guide · UL application guide · NFPA 70
Where can I obtain product and submittal documents?
Use the Download Data Sheet link in the Specifications section for the current Part 7032 technical document. For submittals, certificates, or project-specific documentation not available on the page, contact Syston technical support and identify Part Number 7032, the project, and the exact document required.Sources: Syston data sheet
How do I request pricing and availability?
Use Request a Quote or Speak with an Expert and provide Part Number 7032, jacket color, quantity, package requirements, delivery location, and project timing. Pricing and availability can change and are not inferred from the visual jacket selector. Syston will confirm the current commercial details for the request.Sources: Syston data sheet
Technical references

Product & project support

Request Technical
and Project Support

Need product documentation or help identifying the information for your project? Share the part number, equipment requirements and application with our team.

Contact Product Support

For system design, code applicability and installation, consult a qualified electrician or engineer.

Purchasing & sales

Syston Sales

Request product pricing, samples and ordering details, or find a purchasing channel.

Documents & product information

Syston Resources

Access technical documentation and supporting product information.

Channel partnerships

Become a Distributor

Build a connection with Syston for your wire and cable business. Tell us about your company, markets and product interests to start a distributor conversation.

Explore Distributor Partnership

PROJECT TOOLS · PART 7032 ONLY

Select, plan, and verify.

Use approved Part 7032 facts for an initial fit check, a single-line cable estimate, and source-backed technical answers. Final selection still depends on project documents, equipment requirements, local code, and the authority having jurisdiction.

7032 SELECTOR · LIMITED RELEASE

Check the stated conditions.

This product-scoped check does not search the full Syston catalog. It tests four project inputs against the approved Part 7032 record and returns a cautious selection state.

PRELIMINARY CABLE BOM

Estimate 500 ft reels.

This calculator creates one Part 7032 cable line only. It is not a complete HVAC system bill of materials and does not include price, stock, accessories, labor, or installation approval.

PART 7032 KNOWLEDGE CENTER

Technical depth, when you need it.

These topic paths reuse the approved FAQ and source references already published for Part 7032. They do not add new ratings, approvals, or compatibility claims.

Riser, plenum, and pathway checks Understand what CMR, CL3R, and FT4 communicate—and why the installed route still has to be confirmed.

What does the CMR rating mean?

CMR identifies a communications riser cable rating. It is associated with vertical riser pathways and the applicable flame-test requirements for that cable type. Part 7032 is marked CMR, but the rating does not independently approve every route. Confirm the planned pathway with project documents, local code, and the authority having jurisdiction.

Review FAQ and technical references

What does the CL3R designation mean?

CL3R identifies a Class 3 riser cable designation under the applicable National Electrical Code framework. It describes the listed cable type and intended pathway category; it is not a substitute for a project-specific installation review. Confirm circuit classification, route, equipment instructions, and local requirements before using Part 7032.

Review FAQ and technical references

What does FT4 indicate?

FT4 is a CSA vertical cable-tray flame-test classification. It indicates performance under the referenced vertical tray flame-test method; it does not, by itself, establish universal Canadian approval or suitability for every installation. Confirm all required product markings, certifications, provincial or local rules, and project specifications before installation.

Review FAQ and technical references

When is CMP required instead of CMR?

CMP is the plenum-rated option used where the pathway is classified as a plenum or another space that requires plenum cable. CMR is a riser rating and must not be treated as a substitute where CMP is required. Confirm the actual space classification with project documents, local code, and the authority having jurisdiction.

Review FAQ and technical references

What should be confirmed before routing the cable?

Confirm the pathway classification, environmental exposure, required rating, support method, bend and pulling conditions, separation from other systems, equipment instructions, and local code. The CMR / CL3R / FT4 and sunlight-resistant markings describe verified product attributes, but they do not replace an installation-specific review or approval.

Review FAQ and technical references

Who confirms code compliance for the installation?

The installer and project team should verify the design against the adopted local code, project specifications, equipment instructions, and the authority having jurisdiction, often abbreviated AHJ. Product markings help identify the cable type, but they do not approve a specific pathway or installation on their own.

Review FAQ and technical references
HVAC and thermostat compatibility Check conductor count, terminals, C-wire requirements, equipment diagrams, and route conditions before selection.

Can Part 7032 support a smart thermostat?

Part 7032 may be considered only when the thermostat and HVAC equipment wiring diagrams call for a two-conductor control run. Many smart thermostats require additional conductors or a dedicated common connection. Do not infer compatibility from the thermostat-wire name alone; confirm every terminal and power requirement with the equipment manufacturer.

Review FAQ and technical references

How do I confirm that two conductors are enough?

List the required control terminals at both ends of the run and compare them with the equipment wiring diagram. Part 7032 provides exactly two insulated conductors. If the system requires separate heating, cooling, fan, common, reversing-valve, accessory, or other functions, select a verified conductor count that supports the complete design.

Review FAQ and technical references

Can Part 7032 be used for furnace controls?

Part 7032 is intended for specified low-voltage HVAC control wiring and may fit a furnace control connection that requires two conductors. Suitability depends on the furnace wiring diagram, terminal functions, circuit classification, route, and local requirements. Confirm all five before the cable is ordered or installed.

Review FAQ and technical references

Can Part 7032 be used for air-handler controls?

It may be used for an air-handler control run when the equipment documentation specifies a compatible two-conductor low-voltage circuit. Do not assume that every air handler uses the same terminal arrangement. Verify the control-board diagram, required conductor count, pathway classification, and applicable local rules before installation.

Review FAQ and technical references
Construction and identification Review the 18 AWG, two-conductor, solid bare-copper construction and red/white identification.

What does 18/2 thermostat wire mean?

The “18/2” description means the cable contains two 18 AWG insulated conductors. Part 7032 uses solid bare-copper conductors with red and white insulation inside a round thermostat-cable jacket. It is intended for specified low-voltage HVAC control runs; always confirm the conductor count and pathway before selection.

Review FAQ and technical references

How should buyers interpret 18 AWG?

18 AWG is the American Wire Gauge size of each conductor in Part 7032. It identifies conductor size, but it does not establish system compatibility by itself. The equipment wiring diagram, circuit requirements, run design, pathway rating, and local rules must all be reviewed before the cable is specified or installed.

Review FAQ and technical references

What does two-conductor construction provide?

Two-conductor construction provides one red and one white insulated conductor inside the outer jacket. This can suit control circuits that require two conductors, but it does not support every thermostat or HVAC configuration. Count every required terminal and function on the equipment wiring diagram before ordering Part 7032.

Review FAQ and technical references

Is Part 7032 solid copper or CCA?

Part 7032 is specified with two 18 AWG solid bare-copper conductors. It is not identified in the approved Part 7032 record as copper-clad aluminum (CCA). “Solid” describes each conductor as a single copper core rather than a stranded bundle. Follow the connected equipment’s stripping and termination instructions before making the final connection.

Review FAQ and technical references

How are the two conductors identified?

Part 7032 uses one red insulated conductor and one white insulated conductor inside the outer jacket. Keep the identification consistent from the source equipment to the field device, and label the run when the project requires it. Conductor color does not replace verification against the equipment wiring diagram.

Review FAQ and technical references
Documents, ordering, and project support Confirm the product record, package, jacket option, documentation, pricing, and availability needed for the project.

Do Brown and White jackets differ technically?

Brown and White are visual jacket options for the same Part 7032 construction. The published product specifications do not assign different electrical, flame-test, pathway, or environmental performance to the two colors. Choose the color that supports project identification, then confirm current package availability and ordering details with Syston.

Review FAQ and technical references

Can this product be used outdoors, in wet locations, or for direct burial?

The Part 7032 Premium PVC jacket is identified by the manufacturer as sunlight resistant for specified above-ground pathways. That statement does not independently establish wet-location, underground, direct-burial, or unrestricted outdoor approval. Confirm the complete route, enclosure, moisture exposure, temperature, pathway classification, project documents, local code, and AHJ requirements before installation.

Review FAQ and technical references

What information should I verify before ordering?

Confirm Part Number 7032, 18 AWG, two conductors, solid copper, CMR / CL3R / FT4 ratings, Brown or White jacket, the standard 500-foot package or requested custom length, and the required project quantity. Also verify that the pathway and equipment diagram match a two-conductor riser-rated thermostat cable before placing the order.

Review FAQ and technical references

Where can I obtain product and submittal documents?

Use the Download Data Sheet link in the Specifications section for the current Part 7032 technical document. For submittals, certificates, or project-specific documentation not available on the page, contact Syston technical support and identify Part Number 7032, the project, and the exact document required.

Review FAQ and technical references

How do I request pricing and availability?

Use Request a Quote or Speak with an Expert and provide Part Number 7032, jacket color, quantity, package requirements, delivery location, and project timing. Pricing and availability can change and are not inferred from the visual jacket selector. Syston will confirm the current commercial details for the request.

Review FAQ and technical references

TECHNICAL ASSISTANT · VERIFIED ANSWER MODE

Ask Part 7032.

This first release retrieves approved Part 7032 FAQ answers only. It does not use open-ended generation, store the question, approve an installation, or infer compatibility beyond the governed record.

Need a project-specific review? Include Part Number 7032, the equipment diagram, required conductor count, pathway, route length, environment, quantity, and delivery timing.

Request technical and project support
Spread the love

Additional information

Indoor

Riser

Sheilding

Unshielded

Outdoor

Above Ground

Gauge

18 AWG

Subcategoy

Thermostat Wire (LVT)

Conductor Count

2 Conductor

Conductor Material

Solid Copper

Wire Strengths

Our premium 18/2 thermostat wire offers many benefits:
  • Flexible and easy to peel off, so you or your customers can easily install even in tight corners
  • RhinoPac® packaging solutions are designed to provide smooth pulling during installation while offering reliable protection from crushing and water damage during transport or storage
  • A ripcord underneath the jacket, to make it easy to remove during installation
  • Legend markings for channels, rooms, and zones so installation is faster and easier
  • Ascending and descending E-Z footage markings, so there’s no need for a measuring tape during installation
  • Sunlight-resistant (it complies with the UL 1581 standard in regard to resistance to sunlight in outdoor installations), so it can be installed outdoors if desired
  • CL3R (Riser-Rated) Flame-retardant jacket, for peace of mind in case of fire
  • RoHS compliant, so you can rest easy knowing it doesn’t contain hazardous substances that could harm you, your employees, or your customers (more information about this is in our Green Leaf Label)
  • Third-party verified for guaranteed performance, so it will stand up to your needs or those of your customers
  • Operates in a wide range of temperatures, so it can be installed in any area in any part of North America
  • This 18/2 Thermostat Wire (LVT) and Bell Cable has a thick insulation and is rated to 300-Volt and is classified as a Class-3 (CL3) Power-Limited Circuit Cable. (CL3 cables can carry a surge of up to 300 watts, while CL2 can only carry a surge of up to 150 watts. A CL3-rated cable can take the place of any CL2, however, a CL2 cannot take the place of a CL3)
  • This cable has a thick insulation and is rated to 300-Volt and is classified as a Class-3 (CL3) Power-Limited Circuit Cable. (CL3 cables can carry a surge of up to 300 watts, while CL2 can only carry a surge of up to 150 watts. A CL3-rated cable can take the place of any CL2, however, a CL2 cannot take the place of a CL3)
  • Versatile applications including all kinds of HVAC situations such as wiring low voltage heating and air conditioning controls, bell and annunciator systems, and other low-voltage applications. This cable can be used in both damp or dry locations

Standards Compliances

Our premium 18/2 thermostat wire complies with the following national and international standards:
  • NEC: 725
  • UL Standard: UL 13
  • Flame Rating: UL 1666 (Riser); CSA C22.2 No. 2556 (FT4)
  • ASTM B-3
  • RoHS 3 (EU 2015/863)
  • ISO 9001: 2015
  • ISO 14001: 2015
  • OHSAS 18001

Good to Know

  • Brand: EZ-Pull® from Syston Cable Technology
  • Conductor: Solid Bare Copper
  • Number of Conductors: 2 (Twisted)
  • Size: 18 AWG
  • Insulation: Premium Polyolefin (Flame-Retardant & RoHS Compliant)
  • Conductor Color Code: 1. Red  2. White
  • Ripcord: Applied longitudinally under the jacket
  • Jacket: Premium PVC (Flame-Retardant, Sun Resistantistant & RoHS Compliant)
  • Nominal Cable Diameter (in): 0.130
  • Temperature Rating (°F) Installation: +32 to +140       Storage & Operation: -4 to +167
  • Lengths available: 500 ft
  • Color options: Brown, White
  • Custom cable constructions, lengths, colors, and packaging are available.
 

With the wide variety of wires Syston Cable Technology carries, you are sure to find a Thermostat Wire well-suited to even the most challenging application.

If you have any questions about our products or services, please feel free to contact us via our website or Facebook page.

Specifications

Download the technical specifications sheet for our premium Thermostat Wire 18/2 Riser Rated: 7032.pdf

Become A Distributor

Syston Cable Technology believes in identifying, building and nurturing long term distributor partnerships. We seek well run, established and properly resourced distributor partners that want to grow their business as much as we want to grow ours. Our partnerships begins with our portfolio of high performance cable products with the most competitive price and our well known brands, and continue with an array of support materials and programs to insure our distributor partners are successful in their respective marketplaces.

If you or your company is up for the challenge, and the rewards that come with being a distributor partner, please take a few minutes to complete the application form below and click the SUBMIT button at the bottom. Upon review, we will contact you to complete the application process. All applications are reviewed within 48 hours. 

SYSTON Sales

SYSTON Resources

Translate »